PREFABRICATED BUILDINGS |
|
Type:
FIRE - SAFE |
SPECIFICATIONS
|
|
GENERAL
'FIRE-SAFE'
PORTABLE &
PREFABRICATED BUILDINGS ARE DESIGNED TO PROVIDE INSTANT, HAZARD-FREE
& AESTHETIC ACCOMMODATION FACILITY, ESPECIALLY BUILT FOR USE IN THE
EXTREME CLIMATIC CONDITIONS, COMBINING THE ADVANTAGES OF OCCUPYING
MINIMUM OF SPACE AND TIME FOR ERECTION. THE CONSTRUCTION FEATURES
MODULAR COMPOSITE NON-COMBUSTIBLE PANELS WITH CLASS 1 FIRE-INDEX.
INTERNAL ELECTRICAL, PLUMBING/SANITARY FITTINGS & ACCESSORIES ARE
PRE-INSTALLED, REQUIRING EXTERNAL HOOK-UP TO EXISTING SERVICES AT
THE LOCATION SITE.
SINGLE LIFT:
STANDARD SIZE PREBUILT MODULES ARE 2.4-3.6m WIDE x UPTO 16m IN
LENGTH WITH 2.4-2.8m CLEAR INTERNAL HEIGHT
MULTIPLE:
LARGER, GROUND
OR G+MEZZANINE LEVEL COMPLEXES ARE ACHIEVED WITH PREBUILT MODULES
SUPPLIED & ADJOINED/STACKED ON SITE
|
|
FLOOR BASE
(either portable or modular/prefab, assembled on concrete slab)
PORTABLE:
(SKID-MOUNTED)
STRUCTURAL
CHASSIS FRAME FABRICATED WITH 140x70 PERIPHERY MS CHANNEL, 140X70 MS
I-SECTION LONGITUDINAL
BEAM & LATERAL BEAMS WELDED AT 2.4m SPACING. FLOORDECK IS 18mm WBP
‘KORINDO’ MARINE PLYWOOD FASTENED ON 5½” X 1½” TREATED SPF TIMBER
JOISTS FIXED AT
16”/406mm CENTRES. ALL STEEL FRAMING IS PRIMED WITH RED-OXIDE AND
FINISHED WITH TWO COATS
ALKYD-BASED ENAMEL GLOSS PAINT.
PREFABRICATED:
(CONCRETE SLAB)
MODULAR
CONSTRUCTION FOR SEMI-PERMANENT APPLICATIONS WITH BUILDING ASSEMBLED
ON SITE ON 10 CM. CONCRETE FLOOR SLAB TO PROVIDE MAINTENANCE-FREE
FLOORING WITH ‘ZERO’ LEVEL FOOT-NOISE DISTURBANCE. FLOOR-COVERING IS
EITHER 50X50 ‘HEUGA’ ANTI-STATIC CARPET TILES OR 2mm HEAVY-DUTY
‘MARLEY’ OR ‘TARKETT’ VINYL SHEET, HEAT-WELDED ALONG THE SEAMS &
UPTURNED ALONG THE WALLS.
|
|
WALLS
80mm
THICK, TOUNGE+GROOVE COMPOSITE PANELS, INJECTED WITH 35-40Kg/m³
DENSITY CFC & HCFC-FREE FIRE-RETARDANT POLYURETHANE INSULATING CORE,
BONDED TO 0.7mm COLOUR POWDER-COATED (RAL 9002 – LIGHT GREY)
SHALLOW-RIB ALUMINUM SHEET EXTERNALLY AND 3.2mm PREFINISHED
FIRE-RATED HIGH-PRESSURE PHENOLIC RESIN LAMINATE BOARD INTERNALLY.
PARTITION WALLS ARE 50mm PANELS SAME AS ABOVE WITH FIRE-RATED
LAMINATE BOARD ON EITHER SIDES.
(Please refer
attached Sheet for Technical Data & Properties of Phenolic Resin
Laminate Board)
|
|
ROOF
DOUBLE-PITCH
0.7mm OFF-WHITE COLOUR POWDER-COATED PROFILED ALUMINUM SHEETING
FASTENED ON 50mmx50mm SPF TIMBER PURLINS WITH SELF-DRILLING ROOFING
SCREWS WITH NEOPRENE WASHERS ROOF TRUSSES ARE FABRICATED WITH 50mm x
50mm M.S ANGLE SECTIONS FIXED AT 120 CM CENTRES (1:10 Gradient)
SOFFITS & GABLE ENDS ARE BOX-TYPE CONSTRUCTION CLADDED WITH 6mm
CEMENT-FIBER FASCIA BOARD, COATED WITH UNDERCOAT PRIMER & FINISHED
WITH 2 COATS MATT ENAMEL PAINT. OPTIONAL: CURVED EAVES CLADDING
ALONG THE EAVES
|
|
CEILING
CEILING IS SUSPENDED FALSE-TYPE 9mm
NON-COMBUSTIBLE GYPSUM BOARD FIXED ON 47mm x 47mm TIMBER BATTENS
WITH BEADING STRIPS FIXED ALONG THE JOINTS. CEILING FINISH IS WHITE
LIGHT-TEXTURED PAINT APPLIED ON UNDERCOAT PRIMER. INSULATION IS 80mm
RIGID POLYSTYRENE SLABS
|
|
DOORS
MAIN PERSONNEL ENTRANCE & EMERGENCY
EXIT DOORS ARE WHITE COLOUR POWDER-COATED ALUMINUM DOOR, SIZE 210cm
x 90cm, COMPLETE WITH ARCHITRAVE, DOOR HARDWARE (ALUMINUM HINGES,
PUSH/PULL HANDLES, CYLINDER LOCK WITH 3 KEYS, DOOR CLOSER)
WEATHERSEALS, CLEAR VIEW PANE WITH WIRED SAFETY GLASS. DOOR LOCK
MECHANISM IN FIRE EXIT DOORS IS REPLACED WITH ‘BRITON’ (UK) PANIC
HARDWARE. PARTITION DOORS ARE FLUSH-TYPE, SEMI-SOLID CORE DOOR PANEL
FINISHED IN STAINED TEAK VENEER, SET IN MERANTI TIMBER DOOR
FRAME/ARCHITRAVE, FITTED WITH ‘UNION’ MORTICE LOCK, 3 BRASS HINGES,
DOOR CLOSER & DOOR STOP
|
|
WINDOWS
100cm x 100cm HERMETICALLY SEALED
DOUBLE-GLAZED WITH 6mm REFLECTIVE TEMPERED GLASS EXTERNALLY & 6mm
CLEAR GLASS INSIDE, COLOUR POWDER-COATED ALUMINUM FRAMED, WITH
OPEN ABLE TOP FLAP WITH WEATHERSEAL, INSECT SCREEN & FIXED PANEL
BELOW. ALSO FITTED ARE VENETIAN BLINDS WITH 16mm WHITE ALUMINUM
SLATS.
|
|
ELECTRICAL (COMPLYING WITH DEWA/‘IEE’ STANDARDS)
CABLES ARE B.S. CLASS ‘DUCAB/BICC’ ALL RUNNING IN PVC CABLE CONDUIT
PIPES, CONCEALED INSIDE THE WALLS/CEILING.
FITTINGS INCLUDE:
- 2x36W DOUBLE FLUORESCENT
FIXTURES WITH PRISMATIC DIFFUSER COVER OR REFLECTIVE ALUMINUM
LOUVRES
-
VAPOUR PROOF LIGHT FIXTURE WITH 40W
INCANDESCENT BULB IN BATHROOM & KITCHEN
-
300W EXTERNAL FLOODLIGHTS WITH
PHOTO-CELL SENSOR SWITCH (OPTIONAL)
-
13 AMP PLUG SOCKETS, 20 AMP DP
SWITCH FOR WALL MOUNT AIRCOND (OR WATERPROOF 32AMP ISOLATOR FOR
SPLIT-TYPE AIRCONDS)
-
FIRE EXIT LIGHTS ABOVE THE DOOR &
BATTERY-OPERATED SMOKE DETECTOR
-
BATHROOM MIRROR LIGHT, SHAVER
SOCKETS & EXTRACTOR FAN WITH AUT0-SHUTOFF LOUVRES (‘XPELAIR’ UK OR
EQUIV.)
-
40AMP COOKER SOCKET IN KITCHEN
(OPTIONAL)
-
3PH. DISTRIBUTION BOARD WITH MCCB
INCOMER & BREAKERS (‘ABB’ OR EQUIV.)
|
|
PLUMBING/SANITARY
¾” & ½" SURFACE-MOUNT COPPER AND PVC
PIPES TO PROVIDE HOT/COLD SYSTEM. FITTINGS INCLUDE MAINTENANCE-FREE
CERAMIC WESTERN WC WITH FLUSH TANK (‘IFO’ SWEDEN), CERAMIC WALL
URINALS WITH MANUAL FLUSH PUSH-VALVE, CERAMIC PEDESTAL WASHBASIN
WITH 60X40 BEVELED MIRROR, GRP SHOWER TRAY (80X80) WITH CURTAIN,
SINGLE-BOWL/SINGLE DRAIN STAINLESS STEEL KITCHEN SINK CABINET WITH
MIXER AND WASTE FITTINGS, 40AMP COOKER SOCKET, 50LTRS/12-GALLON
WATER HEATER ‘ARISTON’ & ¾” SINGLE VALVE TO BE PROVIDED EXTERNALLY
FOR ON-SITE CONNECTION.
OPTIONAL:
-
ACCOMMODATION/OFFICE
FURNITURE/APPLIANCES/EQUIPMENT
-
AIR CONDITIONING UNITS (WINDOW, SPLIT
OR PACKAGE TYPE)
-
CIVIL WORKS/CONCRETE FOOTINGS/SITE
INSTALLATION/ERECTION.
-
PVC DRAINAGE CONNECTION INTO EXISTING
SYSTEM (OR EXCAVATION/ INSTALLATION OF FIBERGLASS SEPTIC TANK & PVC
CONNECTION)
-
FRESH WATER CONNECTION FROM EXISTING
SUPPLY POINT (OR PROVISION OF GROUND LEVEL FIBER GLASS WATER STORAGE
TANK WITH ELECTRIC BOOSTER PUMP & CONNECTION)
-
POWER CONNECTION VIA EXPOSED CONDUITED
CABLE OR TRENCHED ARMOURED CABLE, SUITABLY CONNECTED FROM AN
ISOLATOR SWITCH PROVIDED AT THE EXISTING MAINS
DISTRIBUTION BOARD.
-
SURFACE-MOUNTED WHITE PVC TRUNKING FOR
TEL & NETWORKING CABLES
-
FIRE WARNING/DETECTION FITTINGS: FIRE
PANEL WITH CEILING MOUNT SMOKE/HEAT DETECTORS, BREAKGLASS UNITS,
FIRE ALARM BELL
|
|