PREFABRICATED PORTABLE UNIT
SPECIFICATIONS
GENERAL
THE PORTACABINS ARE
DESIGNED TO PROVIDE INSTANT ACCOMMODATION ESPECIALLY SUITABLE FOR
SITE PROJECTS IN THE GULF CLIMATIC CONDITIONS COMBINING THE
ADVANTAGES OF OCCUPYING MINIMUM OF SPACE AND TIME FOR ERECTION. THE
UNIT FEATURES AESTHEtIC FINISHES WITH INTERNAL FITTINGS
FACTORY-INSTALLED, REQUIRING EXTERNAL HOOK-UP TO EXISTING SERVICES
AT PROJECT SITE.
FLOOR
FLOOR CHASSIS IS
FULLY FABRICATED WITH MS STEEL. 100x50mm MS channel PERIMETER frame with longitudinal MS I-beam in the centre
& lateral MS I-beam at 2m
intervals. Flooring is 18mm
‘korindo’ plywood FIXED WITH rivetS on 50mmx50mm MS angle joists.
FLOORING IS
heavy-duty vinyl-FLOORING WITH heat-welded joints. ALL STEEL FRAMING
IS PRIMED WITH RED-OXIDE AND FINISHED WITH TWO COATS OIL-BASED
ENAMEL GLOSS PAINT.
WALLS
Wall panel is 57mm
thick, sandwich-type pre-pressed paNEL, with 6mm
‘korindo’ plywood externally FIXED on 47mm
x 50mm timber
stud-frame and decorative woodgrain style plywood on internal walls.
Insulation is rigid 47mm
polystyrene BOARD. EXTERNAL
WALL SURFACE IS COATED WITH ALL-WEATHER HEAVY-TEXTURED PAINT APPLIED
ON UNDERCOAT PRIMER, PLUS PROTECTIVE WATERPROOF OIL-BASED TOPCOAT.
AIR-COND APERTURES ARE STANDARD FITTED WITH STEEL SUPPORT BRACKETS.
TOILET/KITCHEN WALL FINISH IS PAINTED WIITH TWO COATS
WATERPROOF ENAMEL PAINT WITH SKIRTINGS SUITABLY SEALED WITH SILICONE
SEALANT.
ROOF/CEILING
26G CORRUGATED ALUMINIUM SHEETING FIXED WITH
BITUMEN-WASHER ROOF NAILS ON WHITEWOOD PURLINS. ROOF TRUSSES ARE
DOUBLE PITCHED AT 2.4m SPACING. CEILING IS SUSPENDED TYPE WITH 6mm
BOARD and beadings along the joints, finished with white
light-textured paint. ROOF CAVITY IS INSULATED WITH 50mm
POLYSTYRENE INSULATION.
DOORS
200x90
SEMI-SOLID, FLUSH TYPE SET IN MERANTI FRAME, FITTED WITH ‘UNION’
LOCK AND 3 brASS HINGES. INTERNAL SURFACE IS DECORATIVE BOARD TO
MATCH WITH WALL FINISH. External finish is two coats enamel gloss
paint applied on 4mm
plywood
WINDOWS
90cm x
90cm
ANODISED, ALUMINIUM-FRAMED (‘AL GHURAIR’), HALF-SLIDING, WITH 6mm
CLEAR GLASS AND INSECT SCREEN. EXHAUST WINDOWS ARE
60cm
x 30cm fixed type with 6mm frosted glass panel.
ELECTRICAL
(Complying with ‘DEWA/IEE’ Standards)
Cables are ‘DUCAB-BICC’ conduited and concealed.
- 1.5
mm - lighting
- 2.5
mm
- 13 amp sockets
- 4.0
mm
- 15 amp sockets
Fittings include:
-
2x36W
fluorescent fixtures (JAPAN)
- external waterproof
bulkhead light (German)
- 13 amp and 15 amp
A/C plug sockets (UK)
- water heater 12
gallons ("EverHot” UAE)
- extractor fans (JAPAN)
- light switches (UK)
- distribution board
with MCBs & ELCB (‘MEM’)
PLUMBING/SANITARY
½" copper and PVC pipes to provide hot/cold system.
Fittings include Western WC, urinals, washbasin with mirror, shower
tray (80x80)
with curtain, 1m
SINGLE-BOWL stainless steel kitchen sink CABINET with Mixer and
waste fittings. SINGLE 3/4" valve to be provided externally for
on-site connection.
OPTIONAL
|
1. |
ACCOMMODATION/OFFICE FURNITURE.
|
|
2. |
AIRCONDITIONING UNITS (WINDOW OR SPLIT-TYPE). |
|
3. |
CONCRETE FOOTINGS/SITE INSTALLATION/ERECTION. |
|
4. |
PVC
DRAINAGE CONNECTON INTO EXISTING SYSTEM (OR EXCAVATION &
INSTALLATION OF FIBREGLASS
SEPTIC TANK & PVC CONNECTION).
|
|
5. |
FRESH
WATER CONNECTION FROM EXISTING SUPPLY POINT (OR PROVISION OF FIBREGLASS
OVERHEAD WATER STORAGE TANK & CONNECTION). |
|
6. |
POWER CONNECTION VIA EXPOSED CONDUITED CABLE OR TRENCHED
ARMOURED CABLE,SUITABLY CONNECTED FROM AN ISOLATOR SWITCH
PROVIDED AT THE EXISTING MAINS DISTRIBUTION BOARD. |
|